Filter Models | Flow Rate | Pipe Size | Max.W. Pressure | Max. Oil Content | Filration Grade | Element |
Nm³/min. | BSP | barg | P.P.M ( 21 °C ) | Micron | Quantity | |
EF-700 | 0,7 | ½ “ | 16 | 0,5 | 1 | 1 |
EF-701 | 0,7 | ½ “ | 16 | 0,01 | 0,1 | 1 |
ECF-702 | 0,7 | ½ “ | 16 | 0,008 | …… | 1 |
EF-1200 | 1,2 | ½ “ | 16 | 0,5 | 1 | 1 |
EF-1201 | 1,2 | ½ “ | 16 | 0,01 | 0,1 | 1 |
ECF-1202 | 1,2 | ½ “ | 16 | 0,008 | …… | 1 |
EF-2300 | 2,3 | ¾ “ | 16 | 0,5 | 1 | 1 |
EF-2301 | 2,3 | ¾ “ | 16 | 0,01 | 0,1 | 1 |
ECF-2302 | 2,3 | ¾ “ | 16 | 0,008 | …… | 1 |
EF-3700 | 3,7 | 1 “ | 16 | 0,5 | 1 | 1 |
EF-3701 | 3,7 | 1 “ | 16 | 0,01 | 0,1 | 1 |
ECF-3702 | 3,7 | 1 “ | 16 | 0,008 | …… | 1 |
EF-5500 | 5,5 | 1 “ | 16 | 0,5 | 1 | 1 |
EF-5501 | 5,5 | 1 “ | 16 | 0,01 | 0,1 | 1 |
ECF-5502 | 5,5 | 1 “ | 16 | 0,008 | …… | 1 |
EF-6500 | 6,5 | 1 ½ “ | 16 | 0,5 | 1 | 1 |
EF-6501 | 6,5 | 1 ½ “ | 16 | 0,01 | 0,1 | 1 |
ECF-6502 | 6,5 | 1 ½ “ | 16 | 0,008 | …… | 1 |
EF-11.000 | 11 | 2 “ | 16 | 0,5 | 1 | 1 |
EF-11.001 | 11 | 2 “ | 16 | 0,01 | 0,1 | 1 |
ECF-11.002 | 11 | 2 “ | 16 | 0,008 | …… | 1 |
EF-18.000 | 18 | 2 “ | 16 | 0,5 | 1 | 1 |
EF-18.001 | 18 | 2 “ | 16 | 0,01 | 0,1 | 1 |
ECF-18.002 | 18 | 2 “ | 16 | 0,008 | …… | 1 |
EF-22.000 | 22 | 3 “ | 16 | 0,5 | 1 | 2 |
EF-22.001 | 22 | 3 “ | 16 | 0,01 | 0,1 | 2 |
ECF-22.002 | 22 | 3 “ | 16 | 0,008 | …… | 2 |
EF-33.000 | 33 | 3 “ | 16 | 0,5 | 1 | 3 |
EF-33.001 | 33 | 3 “ | 16 | 0,01 | 0,1 | 3 |
ECF-33.002 | 33 | 3 “ | 16 | 0,008 | …… | 3 |
EF-37.000 | 37 | 3 “ | 16 | 0,5 | 1 | 1 |
EF-37.001 | 37 | 3 “ | 16 | 0,01 | 0,1 | 1 |
ECF-37.002 | 37 | 3 “ | 16 | 0,008 | …… | 1 |
EF-52.000 | 52 | 3 “ | 16 | 0,5 | 1 | 3 |
EF-52.001 | 52 | 3 “ | 16 | 0,01 | 0,1 | 3 |
ECF-52.002 | 52 | 3 “ | 16 | 0,008 | …… | 3 |
EF-60.000 | 60 | NW100 | 16 | 0,5 | 1 | 3 |
EF-60.001 | 60 | NW100 | 16 | 0,01 | 0,1 | 3 |
ECF-60.002 | 60 | NW100 | 16 | 0,008 | …… | 3 |
EF-74.000 | 74 | NW125 | 16 | 0,5 | 1 | 2 |
EF-74.001 | 74 | NW125 | 16 | 0,01 | 0,1 | 2 |
ECF-74.002 | 74 | NW125 | 16 | 0,008 | …… | 2 |
EF-111.000 | 111 | NW150 | 16 | 0,5 | 1 | 3 |
EF-111.001 | 111 | NW150 | 16 | 0,01 | 0,1 | 3 |
ECF-111.002 | 111 | NW150 | 16 | 0,008 | …… | 3 |
EF-120.000 | 120 | NW150 | 16 | 0,5 | 1 | 3 |
EF-120.001 | 120 | NW150 | 16 | 0,01 | 0,1 | 3 |
ECF-120.002 | 120 | NW150 | 16 | 0,008 | …… | 3 |
EF-140.000 | 140 | NW200 | 16 | 0,5 | 1 | 4 |
EF-140.001 | 140 | NW200 | 16 | 0,01 | 0,1 | 4 |
ECF-140.002 | 140 | NW200 | 16 | 0,008 | …… | 4 |
Air in a typical city contains approximately 140 million particles per m³ of air as dust. 90% of these particles are under the size of 2 microns. These particles can easily pass through the suction filter (approximately 5 micron) and enter in the compressor unit and disperse in the air installation together with the pressurised air.
Besides, burned oil contained in the air that comes from the compressor with amount of 6 ppm at least combine with the water and dust in the air and damage the o-rings, seals of all of the equipments that work with pressurised air and cause for the air leakage, corrosion and malfunctioning of the valves.
Additionally, it interferes with the quality for the paint systems. For this reason, filtration of the pressurised air in the industry is rather important. Filters are manufactured with three different sensitivity and they are connected in series in the installation line according to the importance of the place they are used in. The internal parts of the filter, which protect the pressurised air from oil, dust and condensed water, should be changed every 4 to 6 months depending on the daily work period, ambient air conditions and rate of oil leak of the compressor. Filter internal parts should not be tried to be cleaned at all. Blocked element should definitely be changed.
AAG Pressurised Air Filters are 3 types according to their purpose of uses;
1- General Purpose ( Inlet ) Filters : These are the filters that are known with -00 code in the filter series. These are used at the outlet of the compressor, that is they are used at the inlet of the drier. They provide for the filtration of the particles down to 1μ and the oil content that is left behind in the air after filtration is 0.5 ppm maximum and blue coloured internal part is contained inside of the filter.
2- Medium Sensitivity ( Outlet ) Filters : These are the filters that are known with -01 code in the filter series. These are used at the outlet of the drier in order to filter the air, whose humidity has been removed. They provide particle filtration down to .0.1 μ. The oil content that is left behind in the air after filtration is 0.01 ppm maximum and red coloured internal part is contained inside of the filter.
3- Active Carbon Filters : These are the filters that are known with -02 code in the filter series. These are odour filters. The oil content that is left behind in the air after filtration is 0.008 ppm maximum.
» Aluminun profil body has covered by electrostatics dust paint proof rust and corrosion
» Easy replace of inlet element
» Manual discharge
» Optional timed drain
» Optional mini float discharge
» Optional zero air loss discharge
» High effeciency filtration
» European standart design
Emek compressor was established in 1979, since it’s establishment , it is the manufacturer of piston air compressors, high pressure air compressors, screw air compressors, gas compressors , air dryers and air filters . Besides, supply the service , repairs and the spare parts of whole products .