Home » Our Products » Air Dryers

Paccom Series

Paccom Series Technical Specifications

Modelsbarpsim3/1′m3/hcfmCmp
hp
V/
Ph/
Hz
Conn. SizeLWHKgGas
PACCOM 900162320,954,0 31,8 1/5230/1/50 1/2 “41532554030R-134 a
PACCOM 1200162321,272,0 42,4 1/5230/1/50 1/2 “41532559531R-134 a
PACCOM 1800162321,8108,0 63,6 1/4230/1/50 3/4″41532562532R-134 a
PACCOM 2200162322,2132,0 77,7 1/4230/1/50 3/4″41532566732R-134 a
PACCOM 2600162322,6156,0 91,9 3/8230/1/50 1″55846869544R-134 a
PACCOM 3100162323,1186,0 109,6 3/8230/1/50 1″55846872445R-134 a
PACCOM 3700162323,7222,0 130,8 1/2230/1/50 1″55846875547R-134 a
PACCOM 5500162325,5330,0 194,4 3/4230/1/50 1″65250599779R-134 a
PACCOM 6500162326,5390,0 229,71230/1/50 1-1/2″65250599783R404A
PACCOM 8500162328,5510,0 300,42400/3/502 “8705901200140R404A
PACCOM 110001623211,0660,0 388,72400/3/502 “8705901200140R404A
PACCOM 130001623213,0780,0 459,42,5400/3/502 “8527341191150R404A
PACCOM 178001623217,81.068,0 629,13400/3/502 “8527341191180R404A
PACCOM 200001623220,01.200,0 706,84400/3/502-1/2″8527341191195R404A
PACCOM 255001623225,51.530,0 901,24400/3/502-1/2″11027821372273R404A
PACCOM 300001623230,01.800,0 1060,25400/3/502-1/2″11027821372284R404A
PACCOM 355001623235,52.130,0 1254,66400/3/503″13528331382302R404A
PACCOM 400001623240,02.400,0 1413,67400/3/503″21048041625336R404A
PACCOM 450001623245,02.700,0 1590,37400/3/503″21048041625365R404A
PACCOM 500001623250,03.000,0 1767,010400/3/50DN 10021048041625552R404A
PACCOM 600001623260,03.600,0 2120,410400/3/50DN 10021048041625575R404A
PACCOM 710001623271,04.260,0 2509,112400/3/50DN 100210411501625590R404A
PACCOM 800001623280,04.800,0 2827,213400/3/50DN 100210411501625710R404A
PACCOM 900001623290,05.400,0 3180,615400/3/50DN 100210413601625775R404A
PACCOM 10600016232106,06.360,0 3746,018400/3/50DN 125260013601760805R404A
PACCOM 12000016232120,07.200,0 4240,820400/3/50DN 125275013601760865R404A
PACCOM 14000016232140,08.400,0 4947,625400/3/50DN 125275013601760930R404A

General Information

In the atmospheric air Compressor absorbs, there is always a variable amount of water vapor.

When this moisture and air reach at a certain value by force of Compressor together, water vapor condenses into water under the effect of pressure and cooling.Liquid water is formed at every pressure and temperature changes.

This liquid water causes diameter lossed and causes diametter losses and rusting in the air installation, damages in pneumatic systems and besides several problems that trigger eachother.These damages that cause loss of work, time and Money in the processes are prevented by discharging liquid water occuring in cooling of compressed air (+3 dew point temp.) by refrigerated air dryer.

Clean and dry compressed air takes operation costs down and provide your instruments to work efficient.

Why Compac:

» Small size, full hardware,
» Perfect result to air-water separation,
» Zero air loss as optional,
» Smarter and chip control. Seasonal adjustment does not to need,
» Easy and simple a by-pass line with inlet and outlet filters,
» The advantage of disassembly and assembly for the Heat Exchanger,
» Environment friendly
» Efficient heat transfer
» European standart Design

Why Paccom

»Small size, full hardware
»Perfect result in air-water separation
»Optional zero air loss
»No need for seasonal adjustments with micro chip controlled smart electronic card
»Easy and simple by-pass installation with inlet and outlet filters.
»Dismantling and assembly superiority of the heat exchanger.
»Environmentally friendly.
»High efficiency heat transfer.
»Fully compatible with European standards.

Products Related to Air Dryers